Skip to main content
Tekmar Link

Tekmar Zone Valve Control, Six Zones with Priority

SKU: 306V

$316.00 

Price

See All locations

Shop our locations nearest Zip Code 43085 [change]

Questions About Tekmar 306V?
Innovations by VP has professionals available to assist you with your selection from Tekmar
Email an Expert

More Like This

Product Details

Tekmar 306V

The zone valve control 306 V connects up to six thermostats and operates zone valves to provide heating to a zoned hydronic heating system. The 306V operates a system pump whenever a zone valve opens. Zone 1 can operate either a zone valve or a circulator to provide heat to an indirect domestic hot water tank with optional priority over zones 2 through 6. The 306V includes optional exercising to prevent circulator seizure when not in use and optional post purge operation of the domestic hot water tank to maximize energy savings. The 306V provides a RoomResponse signal to modulating-condensing boilers to optimize comfort while improving boiler efficiency.


  • Finish Blue
  • UPC 779655030617
  • Online Product ID 9574639
  • Width 10.69"
  • Height 8.19"
  • Depth 2.38"
  • Warranty 3 years Limited
  • Prop65 Warning Warning: This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Ambient Temperature Range 32 to 122 degree F
  • Boiler Mix Modulating Output 0 - 10 VDC, 500 Ohm Minimum Load Impedance, 4 - 20 mA, 1 kOhm Maximum Load Impedance
  • Control Load 7 VA
  • Control Type Microprocessor
  • Enclosure Material Abs,Galvanized Steel
  • Fuses T5A 250 V Slow Blow, (2) Spare Fuses Included
  • Indoor Outdoor Indoor
  • Nema Rating NEMA 1
  • Power Supply 115 VAC plus /-10 percent , 60 Hz, 11 A
  • Relative Humidity <=90 percent Non-Condensing
  • Relay End Switch Relay: Boiler, DHW 24 VAC, 5 A, System Pump Relay: 230 VAC, 5 A, 1/3 hp
  • Safetylist CSA C US
  • Suitable For Use With 2, 3 and 4-Wire Zone Valves
  • Transformer 80 VA, 24 VAC
  • Shipping  6 lbs.

Additional information

  • Pump exercising, post purge
  • CSA approved
  • Fuses protect transformers and pumps
  • Compatible with 2, 3 and 4-wire zone valves, unlimited zone expansion
  • Four ground screws, top, bottom and back conduit knockouts
  • LED for each zone, priority, end switch and RoomResponse, away signal shared between tekmar thermostats
  • RoomResponse signal, compatible with all low voltage thermostats
  • Two spare fuses included
  • Zone priority, priority override

About This Brand